Gafchromic™ films are designed to provide fast and highly accurate measurements for radiotherapy and radiology applications.
When used with specifically designed filmQA pro™ software, Gafchromic™ film provides the most complete and accurate dosimetric measurement. Instant high resolution images provide the data integrity needed to increase confidence and peace of mind.
product | use | recommended dose range | recommended energy range | format | product code |
---|---|---|---|---|---|
EBT3 | Patient QA: IMRT, VMAT, brachytherapy Machine QA: Star Shot test, Picket Fence test, Flatness and Symmetry test | 0.2 Gy to 10 Gy | 100keV into the MV range | Box of 25 sheets: size 8 × 10 in Box of 10 sheets: size 12.8 × 17 in |
828204 828206 |
EBT4 | Patient QA: IMRT, VMAT, brachytherapy Machine QA: Star Shot test, Picket Fence test, Flatness and Symmetry test | 0.2 Gy to 10 Gy | 100keV into the MV range | Box of 25 sheets: size 8 × 10 in Box of 10 sheets: size 12.8 × 17 in |
973857 973882 |
EBT3P | EBT3 with the added bonus of punched holes in the film for use with the Gafchromic Quick Phantom | 0.2 Gy to 10 Gy | 100keV into the MV range | Box of 25 sheets: size 8 × 10 in | 841975 |
EBT-XD | Functional for extended dose ranges. Suitable for SRS/SBRT | 0.4 Gy to 40 Gy | 100keV into the MV range | Box of 25 sheets: size 8 × 10 in | 859138 |
HD-V2 | High dose dosimetry for use with beams of photons, electrons, protons, and neutrons. | 10 Gy to 1000 Gy | 100keV into the MV range | Only available in boxes of 10 sheets | 828210 |
MD-V3 | Designed for the measurement of the absorbed dose of high-energy photons. | 1 Gy to 100 Gy | 100keV into the MV range | Box of 5 sheets: size 5 × 5 in | 828213 |
RTQA2-1010 | Machine QA: light field alignment tests, radiation field alignment tests, Star Shot test, Picket Fence test, Flatness and Symmetry test | 0.2 Gy to 10 Gy | 100keV into the MV range | Box of 25 sheets: size 10 × 10 in | 828217 |
RTQA2-111 | Machine QA: light field alignment tests, brachytherapy | 0.2 Gy to 10 Gy | 100keV into the MV range | Box of 25 strips: size 1.25 × 11 in | 828218 |
RTQA2-1417 | Machine QA for larger fields: light field alignment tests, radiation field alignment tests, Star Shot test, Picket Fence test, Flatness and Symmetry test | 0.2 Gy to 10 Gy | 100keV into the MV range | Box of 10 sheets: size 13.8 × 17 in | 828219 |
XR-CT3 | Measure radiation beam slice-width and beam position alignment on CT scanners | 2 cGy to 20 cGy | ~20 keV to 200 keV | Box of 50 strips: size 10 × 19 cm | 972416 |
XR-RV3 | Surface-peak skin dose measurement in interventional procedures guided by fluoroscopy | 0.2 Gy to 10 Gy | ~30 keV to 30 MeV | Box of 25 sheets: size 13.8 × 17 in Comparator Strip 1 each |
832846 828231 |
XR-M3 | Mammography QA Testing | 2 cGy to 20 cGy | ~20 keV to 200 keV | Box of 50 strips: size 6.5 × 2.3 cm | 972417 |
LD-V1 | QA tool for radiology applications | 2 cGy to 20 cGy | ~20 keV to 200 keV | Box of 10 sheets: size 10 × 12 in Box of 10 sheets: size 8 × 10 in |
972413 972412 |
product | product code | format | pieces | pairs |
---|---|---|---|---|
gafchromic film EBT4 | ||||
ballcube I | 973883 | 2.5 × 2.5 in | 20 | 10 |
ballcube II | 973884 | 2.5 × 2.5 in | 20 | 10 |
AQA | 973885 | 2.5 × 2.5 in | 100 | — |
mini ballcube | 973886 | 1.25 × 1.25 in | 20 | 10 |
XLT | 973887 | 1.25 × 1.25 in | 20 | 10 |
gafchromic film EBT-XD | ||||
ballcube I | 873549 | 2.5 × 2.5 in | 20 | 10 |
ballcube II | 873550 | 2.5 × 2.5 in | 20 | 10 |
AQA | 873547 | 2.5 × 2.5 in | 100 | — |
mini ballcube | 873548 | 1.25 × 1.25 in | 20 | 10 |
XLT | 873548 | 1.25 × 1.25 in | 20 | 10 |
product | product code | description |
---|---|---|
gafchromic in-vivo dosimetry system | 987963 | gafchromic in-vivo dosimetry system filmQA pro-v8 with scanner |
gafchromic in-vivo dosimetry system | 990186 | gafchromic in-vivo dosimetry system filmQA pro-v8 without scanner |
gafchromic in-vivo dosimetry system | 987961 | gafchromic pnt-dosr device (53 devices per box) |
A Sophisticated, Quantitative Analysis Tool for Gafchromic™ Film.
FilmQA Pro™ software is a sophisticated, quantitative analysis tool specifically designed to simplify and streamline the intensity-modulated radiation therapy quality assurance (IMRT QA). Our software is also effective for QA of SRS, SBRT and VMAT procedures. It allows you to scan or open images of exposed film and calculate the optimized dose maps.
FilmQA Pro™ software uses proprietary multi-channel dosimetry which eliminates or mitigates film and scanner artifacts by detecting whether errors are being made during scanning. In addition,, the software also has the one-scan analysis feature which combines calibration and plan verification in a single scan. The one-scan protocol requires only the patient film, a reference patch, and an unexposed patch. This protocol eliminates error sources such as interscan variability, which enables you to reduce errors to within 2 percent.
With FilmQA Pro™ software, you can get your results in minutes, post-exposure growth is no longer an issue and there is no waiting overnight for changes in the film to diminish. You can do an analysis any time you want, even at a moment’s notice. The software delivers gamma passing rates ≥ 95 percent at 2 percent at 2 mm instead of using 3 percent at 3 mm.
Vertec has been selling quality assurance products since 1979 and has a wealth of experience. Get in touch with our product specialists to find out more.
To provide the best experience, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behaviour or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.