Radiology & radiotherapy Quality Assurance Software

ARTISCAN by Aquilab

A Simple, 4 Step Solution to QA

f6761c2041e2-Artiscan-define1-1024x769

Define

First complete an inventory of the systems you would like to scope into your QA program along with the associated QA procedures and baseline values/tolerances.

98dc90dc2c9d-artiscane-perso2-1024x769

Plan

Customise your quality assurance processes to balance the demands of maintaining compliance and achieving patient throughput. Build a schedule.

6aab7b6b9231-artiscan-exe-3-1024x764

Execute

Once QA procedures are underway, ARTISCAN will perform automated data analysis against pre-defined quality protocols. Evaluating results is simple thanks to colour coded values linked to tolerances.

c4d03619490a-artiscan-follow-4-1024x764

Follow

Monitoring trends and deviation from baseline values is easy thanks to fully automated, web based reports. Simply log onto the portal from anywhere to get access to all testing at a glance.

Explore the Applications

SPECT QA Pack:

For compliance with IEC 61675-1 & NEMA NU 1-2007

Functional Checks: Motion controls, Safety Indicators, Displays, Collimator Mounts, Anti-collision systems, e-stops.

Planar Mode: Non-uniformity, spectrometry and energy resolution, pixel size, resolution and spatial non-linearity, sensitivity, multi-window spatial recording.

Full Body mode: Non-uniformity, spatial resolution.

Tomographic Mode: Spectrometry angular variation, contiuous mode rotation speed, center of rotation, spatial resolution of reconstructed slice.

Supported Phantoms: All data spectrum Jaszczak phantoms, any 4 quadrant sight models. 

A PET QA Pack is also available for automatic analysis of DICOM images acquired with different test objects.

Machine Quality for Radiotherapy

A wide range of features allow complete compliance of radiotherapy systems:

Multi-leaf collimator (STATIC, IMRT, VMAT) QA
EPID QA
Isocenter QA (Imaging, Mechanical, Treatment, Rotational Axis)
Dosimetry QA
On-Board Imaging QA
Machine Specific QA (Halcyon, Tomotherapy & Radixact)

Find out more

Radiology QA Solution for all Modalities:

Automated CT QA Pack:

Analysis of DICOM phantom images to determine: Signal/noise, signal, homogeneity. Thickness, Position, Increment and slice profile. HU linearity. Low and high contrast resolution. Analysis of certain OEM (Siemens, Philips, GE) water phantoms and inserts. AQUILAB CT laser phantom  for controlling patient movement in z-axis. Dedicated density control pack also available.

MRI QA Pack: 

For analysis of signal/noise, noise. Uniformity. Ghosting. Geometric Distortion. Spatial Linearity. Pixel Size. Contrast Scale. Slice Position. Slice Thickness. High contrast and low contrast resolution.

X-Ray QA Pack:

Allows calculation and monitoring of centering, brightness & contrast, geometric distortion, contrast resolution and spatial resolution. Supporting Leeds Test Object TOR 18 FG, Digi 13 IBA, Normi 13 PTW.

 

Find out more

 

Ready to Automate your QA?

Vertec first began selling QA products in 1979, our product specialists have a wealth of experience and would be happy to advise you further.